NAME

hpialarms – A openhpi sample application that shows "Alarm Control" management instruments

SYNOPSIS


hpialarms[-D id][-N host[:port]][-C<cfgfile>]
         [-a 1 | 0][-b 1 | 0][-c 1 | 0][-m 1 | 0][-n 1 | 0][-p 1 | 0][-i n][-o][-X][-h] hpialarms[--domain = id][--host = host[:port]][--cfgfile = file]
                                                                                                 [--diska = 1 | 0][--diskb = 1 | 0][--critical = 1 | 0][--major = 1 | 0]
                                                                                                 [--minor = 1 | 0][--power = 1 | 0][--chassisid = n][--all][--debug][--help]

DESCRIPTION

hpialarms walks the RPT (Resource Presence Table) for resources that have “Alarm Control” management instruments (SAHPI_CTRL_LED).

If no domain or host is selected, hpialarms uses the default domain as specified in the openhpiclient.conf file.

OPTIONS

(No Option) Display alarm states

Help Options:

-h, –help
Show help options

Application Options:

-c 1|0, –-critical=1|0
Set critical alarm on|off
-m 1|0, –-major=1|0
Set major alarm on|off
-n 1|0, –-minor=1|0
Set minor alarm on|off
-a 1|0, –-diska=1|0
Set diska alarm on|off
-b 1|0, –-diskb=1|0
Set diskb alarm on|off
-p 1|0, –-power=1|0
Set power alarm on|off
-i n, –-chassisid=n
Set chassis id on for n seconds
-o, –-all
Set all alarms off
-D nn, –domain=nn
Select domain id nn
-X, –debug
Display debug messages
-N "host[:port]", –host="host[:port]"
Open session to the domain served by the daemon at the specified URL (host:port). This option overrides the OPENHPI_DAEMON_HOST and OPENHPI_DAEMON_PORT environment variables. If host contains ‘:’ (for example IPv6 address) then enclose it in square brackets. For example: “[::1]” or “[::1]:4743”.
-C "file", –cfgfile="file"
Use passed file as client configuration file. This option overrides the OPENHPICLIENT_CONf environment variable.

SAMPLE OUTPUT

hpialarmpanel ver 0.6 RptInfo : UpdateCount = 5, UpdateTime = 8a2dc6c0 rptentry[0] resourceid = 1 tag : Mullins
RDR[45] : ctltype = 2 : 1 oem = 0 Chassis Identify Control
RDR[48] : ctltype = 0 : 1 oem = 10 Front Panel Power Alarm LED state = off
RDR[51] : ctltype = 0 : 1 oem = 13 Front Panel Minor Alarm LED state = ON
RDR[46] : ctltype = 0 : 0 oem = 0 Cold Reset Control
RDR[49] : ctltype = 0 : 1 oem = 11 Front Panel Critical Alarm LED state = off
RDR[50] : ctltype = 0 : 1 oem = 12 Front Panel Major Alarm LED state = off

SEE ALSO

         hpi_shell
         hpidomain      hpigensimdata  hpireset       hpitop
         hpiel          hpiinv         hpisensor      hpitree
         hpievents      hpionIBMblade  hpisettime     hpiwdt
         hpifan         hpipower       hpithres       hpixml
         ohdomainlist   ohhandler      ohparam

AUTHORS

Authors of this man page:


Peter D Phan(pdphan[at] users.sourceforge.net)
    Ulrich Kleber(ulikleber[at] users.sourceforge.net)
        Anton Pak(avpak[at] users.sourceforge.net)