NAME

pcp-verify – verify aspects of a PCP installation

SYNOPSIS

pcp [pcp options] verify [-c/–containers] [-s/–secure] [-v/–verbose]

DESCRIPTION

pcp-verify inspects various aspects of a PCP collector installation and reports on whether it is configured correctly for certain modes of operation.

By default, pcp-verify checks that PMCD is running and no agents are in a failed state. These checks can be extended and refined using the command line.

OPTIONS

Additional options are available for changing the verification performed by pcp-verify.

-c/–containers verifies the collector installation for monitoring containers.

-s/–secure verifies that the required components for encrypted communication are in place.

-v/–verbose increase the verbosity, and report on each check as it is made. In the absence of any issues found, pcp-verify operates silently.

DIAGNOSTICS

pcp-verify will exit with a non-zero status if it finds anything worth reporting, otherwise it is silent and returns zero.

SEE ALSO

pcp(1) and PCPIntro(1).