cpclean (1) Linux Manual Page
cpclean – Remove wrong control points by statistical methods
Synopsis
cpclean [options] input.ptoDescription
cpclean uses statistical methods to remove wrong control points.Step 1 optimises all images pairs, calculates for each pair mean and standard deviation and removes all control points with error bigger than mean+n*sigma.
Step 2 optimises the whole panorama, calculates mean and standard deviation for all control points and removes all control points with error bigger than mean+n*sigma.
Options
- -o output.pto
- Output Hugin PTO file. Default: ‘<filename>_clean.pto’.
- -n num
- distance factor for checking (default: 2)
- -p
- do only pairwise optimisation (skip step 2)
- -w
- do optimise whole panorama (skip step 1)
- -s
- skip optimisation step when optimising the whole panorama
- -l
- also include line control points for calculation and filtering in step 2
- -h
- shows help