ipmiconsole.conf (5) - Linux Manuals
ipmiconsole.conf: specify default values to FreeIPMI
NAME
freeipmi.conf - specify default values to FreeIPMIDESCRIPTION
The FreeIPMI configuration file can be used to set alternate default values to many FreeIPMI tools so values don't have to be configured on the command line. This allows users to avoid typing in a long list of command line options everytime a command is executed. It can also be used to hide usernames, passwords, and other sensitive information from the ps(1) command.Currently, the tools that can be configured with the configuration file are: bmc-config(8), bmc-device(8), bmc-info(8), bmc-watchdog(8), ipmi-chassis(8), ipmi-chassis-config(8), ipmi-fru(8), ipmi-oem(8), ipmi-pef-config(8), ipmi-pet(8), ipmi-raw(8), ipmi-sel(8), ipmi-sensors(8), ipmi-sensors-config(8), ipmiconsole(8), and ipmipower(8).
By default, the configuration file is stored at /etc/freeipmi//freeipmi.conf. But users may select a different configuration file at the command line with the --config-file option.
Values specified on the command line override the configuration values specified in the configuration file.
FORMAT
The configuration options that can be specified in the configuration file are listed below. Each configuration option must be listed on a separate line. Arguments for an option are separated by any amount of whitespace. Multiple arguments are also separated by whitespace. Comments can be marked by using the pound sign ("#") character, and lines can be continued on the next using backslash ("\").Note that it is possible to list the username, password and other potentially sensitive information in the configuration file. If this data is stored in a configuration file, system administrators should limit access to this file.
GENERAL OPTIONS
The following options are options generally available to all tools, although specific options may be ignored by some. (For example, ipmiconsole(8) and ipmipower(8) do not perform in-band communication, therefore they would ignore in-band communication options. Similarly bmc-watchdog(8) does not perform out-of-band communication, therefore it would ignore all out-of-band options).- driver-type IPMIDRIVER
- Specify the default driver type to use.
- disable-auto-probe ENABLE|DISABLE
- Specify if IPMI devices should be probed for default settings.
- driver-address DRIVER-ADDRESS
- Specify the default in-band driver address to use.
- driver-device DEVICE
- Specify the default in-band driver device path to use.
- register-spacing REGISTER-SPACING
- Specify the default in-band driver register spacing to use.
- target-channel-number CHANNEL-NUMBERFR
- Specify the default in-band driver target channel number.
target-slave-address SLAVE-ADDRESSFR- Specify the default in-band driver target slave address.
username USERNAME - Specify the default username to use.
- password PASSWORD
- Specify the default password to use.
- k_g str
- Specify the default BMC key (K_g) to use. Prefix with '0x' to enter the key in hex.
- session-timeout MILLISECONDS
- Specify the default session timeout length to use in milliseconds.
- retransmission-timeout MILLISECONDS
- Specify the default retransmission timeout length to use in milliseconds.
- authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- workaround-flags WORKAROUNDS
- Specify default workaround flags to use. Multiple workarounds can be specified separated by whitespace. Please see tool manpages for details about available workarounds for each tool. The following workarounds are supported: assumeio, spinpoll, idzero, forcepermsg, unexpectedauth, endianseq, noauthcodecheck, authcap, nochecksumcheck, intel20, supermicro20, sun20, opensesspriv, integritycheckvalue, assumemaxsdrrecordcount, solpayloadsize, solport, solstatus, skipchecks, assumesystemevent, discretereading, ignorescanningdisabled, assumebmcowner, ignoreauthcode, slowcommit, veryslowcommit, solchannelassumelanchannel, ignorestateflag, malformedack.
SDR OPTIONS
The following options are specific to tools that use the sensor data repository (SDR). They will be ignored by all other tools.- quiet-cache ENABLE|DISABLE
- Specify if cache creation/deletion information should not be output by default.
- sdr-cache-directory DIRECTORY
- Specify the default sdr cache directory to use.
HOSTRANGED OPTIONS
The following options are specific to tools that support hostranged output. They will be ignored by all other tools.- buffer-output ENABLE|DISABLE
- Specify if hostranged output should be buffered by default.
- consolidate-output ENABLE|DISABLE
- Specify if hostranged output should be consolidated by default.
- fanout COUNT
- Specify the default multiple host fanout to use.
- eliminate ENABLE|DISABLE
- Specify if undetected hosts should be eliminated by default.
- always-prefix ENABLE|DISABLE
- Specify if output should be always prefixed by default.
BMC-CONFIG OPTIONS
The following options are specific to bmc-config(8). They will be ignored by other tools.- bmc-config-username USERNAME
- Specify the default username to use for bmc-config(8). If specified, will override the general option username above.
- bmc-config-password PASSWORD
- Specify the default password to use for bmc-config(8). If specified, will override the general option password above.
- bmc-config-k_g str
- Specify the default BMC key (K_g) to use for bmc-config(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- bmc-config-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for bmc-config(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- bmc-config-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for bmc-config(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- bmc-config-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for bmc-config(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- bmc-config-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for bmc-config(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see bmc-config(8) manpage for available workarounds.
- bmc-config-verbose-count COUNT
- Specify default verbose count to use for bmc-config(8).
BMC-DEVICE OPTIONS
The following options are specific to bmc-device(8). They will be ignored by other tools.- bmc-device-username USERNAME
- Specify the default username to use for bmc-device(8). If specified, will override the general option username above.
- bmc-device-password PASSWORD
- Specify the default password to use for bmc-device(8). If specified, will override the general option password above.
- bmc-device-k_g str
- Specify the default BMC key (K_g) to use for bmc-device(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- bmc-device-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for bmc-device(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- bmc-device-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for bmc-device(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- bmc-device-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for bmc-device(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- bmc-device-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for bmc-device(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see bmc-device(8) manpage for available workarounds.
BMC-INFO OPTIONS
The following options are specific to bmc-info(8). They will be ignored by other tools.- bmc-info-username USERNAME
- Specify the default username to use for bmc-info(8). If specified, will override the general option username above.
- bmc-info-password PASSWORD
- Specify the default password to use for bmc-info(8). If specified, will override the general option password above.
- bmc-info-k_g str
- Specify the default BMC key (K_g) to use for bmc-info(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- bmc-info-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for bmc-info(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- bmc-info-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for bmc-info(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- bmc-info-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for bmc-info(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- bmc-info-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for bmc-info(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see bmc-info(8) manpage for available workarounds.
- bmc-info-interpret-oem-data ENABLE|DISABLE
- Specify if bmc-info should attempt to interpret OEM data by default or not.
BMC-WATCHDOG OPTIONS
The following options are specific to bmc-watchdog(8). They will be ignored by other tools.- bmc-watchdog-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for bmc-watchdog(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see bmc-watchdog(8) manpage for available workarounds.
- bmc-watchdog-verbose-logging ENABLE|DISABLE
- Specify if logging will be verbose by default.
- bmc-watchdog-no-logging ENABLE|DISABLE
- Specify if logging will be disabled by default.
IPMI-CHASSIS OPTIONS
The following options are specific to ipmi-chassis(8). They will be ignored by other tools.- ipmi-chassis-username USERNAME
- Specify the default username to use for ipmi-chassis(8). If specified, will override the general option username above.
- ipmi-chassis-password PASSWORD
- Specify the default password to use for ipmi-chassis(8). If specified, will override the general option password above.
- ipmi-chassis-k_g str
- Specify the default BMC key (K_g) to use for ipmi-chassis(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- ipmi-chassis-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for ipmi-chassis(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- ipmi-chassis-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for ipmi-chassis(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- ipmi-chassis-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for ipmi-chassis(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- ipmi-chassis-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for ipmi-chassis(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see ipmi-chassis(8) manpage for available workarounds.
IPMI-CHASSIS-CONFIG OPTIONS
The following options are specific to ipmi-chassis-config(8). They will be ignored by other tools.- ipmi-chassis-config-username USERNAME
- Specify the default username to use for ipmi-chassis-config(8). If specified, will override the general option username above.
- ipmi-chassis-config-password PASSWORD
- Specify the default password to use for ipmi-chassis-config(8). If specified, will override the general option password above.
- ipmi-chassis-config-k_g str
- Specify the default BMC key (K_g) to use for ipmi-chassis-config(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- ipmi-chassis-config-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for ipmi-chassis-config(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- ipmi-chassis-config-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for ipmi-chassis-config(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- ipmi-chassis-config-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for ipmi-chassis-config(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- ipmi-chassis-config-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for ipmi-chassis-config(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see ipmi-chassis-config(8) manpage for available workarounds.
- ipmi-chassis-config-verbose-count COUNT
- Specify default verbose count to use for ipmi-chassis-config(8).
IPMI-DCMI OPTIONS
The following options are specific to ipmi-dcmi(8). They will be ignored by other tools.- ipmi-dcmi-username USERNAME
- Specify the default username to use for ipmi-dcmi(8). If specified, will override the general option username above.
- ipmi-dcmi-password PASSWORD
- Specify the default password to use for ipmi-dcmi(8). If specified, will override the general option password above.
- ipmi-dcmi-k_g str
- Specify the default BMC key (K_g) to use for ipmi-dcmi(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- ipmi-dcmi-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for ipmi-dcmi(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- ipmi-dcmi-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for ipmi-dcmi(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- ipmi-dcmi-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for ipmi-dcmi(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- ipmi-dcmi-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for ipmi-dcmi(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see ipmi-dcmi(8) manpage for available workarounds.
- ipmi-dcmi-interpret-oem-data ENABLE|DISABLE
- Specify if ipmi-dcmi should attempt to interpret OEM data by default or not.
IPMI-FRU OPTIONS
The following options are specific to ipmi-fru(8). They will be ignored by other tools.- ipmi-fru-username USERNAME
- Specify the default username to use for ipmi-fru(8). If specified, will override the general option username above.
- ipmi-fru-password PASSWORD
- Specify the default password to use for ipmi-fru(8). If specified, will override the general option password above.
- ipmi-fru-k_g str
- Specify the default BMC key (K_g) to use for ipmi-fru(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- ipmi-fru-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for ipmi-fru(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- ipmi-fru-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for ipmi-fru(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- ipmi-fru-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for ipmi-fru(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- ipmi-fru-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for ipmi-fru(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see ipmi-fru(8) manpage for available workarounds.
- ipmi-fru-verbose-count COUNT
- Specify default verbose count to use for ipmi-fru(8).
- ipmi-fru-bridge-fru ENABLE|DISABLE
- Specify if FRU entries on other controllers should be read by default or not.
- ipmi-fru-interpret-oem-data ENABLE|DISABLE
- Specify if ipmi-fru should attempt to interpret OEM data by default or not.
IPMI-OEM OPTIONS
The following options are specific to ipmi-oem(8). They will be ignored by other tools.- ipmi-oem-username USERNAME
- Specify the default username to use for ipmi-oem(8). If specified, will override the general option username above.
- ipmi-oem-password PASSWORD
- Specify the default password to use for ipmi-oem(8). If specified, will override the general option password above.
- ipmi-oem-k_g str
- Specify the default BMC key (K_g) to use for ipmi-oem(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- ipmi-oem-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for ipmi-oem(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- ipmi-oem-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for ipmi-oem(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- ipmi-oem-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for ipmi-oem(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- ipmi-oem-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for ipmi-oem(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see ipmi-oem(8) manpage for available workarounds.
- ipmi-oem-verbose-count COUNT
- Specify default verbose count to use for ipmi-oem(8).
IPMI-PEF-CONFIG OPTIONS
The following options are specific to ipmi-pef-config(8). They will be ignored by other tools.- ipmi-pef-config-username USERNAME
- Specify the default username to use for ipmi-pef-config(8). If specified, will override the general option username above.
- ipmi-pef-config-password PASSWORD
- Specify the default password to use for ipmi-pef-config(8). If specified, will override the general option password above.
- ipmi-pef-config-k_g str
- Specify the default BMC key (K_g) to use for ipmi-pef-config(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- ipmi-pef-config-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for ipmi-pef-config(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- ipmi-pef-config-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for ipmi-pef-config(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- ipmi-pef-config-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for ipmi-pef-config(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- ipmi-pef-config-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for ipmi-pef-config(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see ipmi-pef-config(8) manpage for available workarounds.
- ipmi-pef-config-verbose-count COUNT
- Specify default verbose count to use for ipmi-pef-config(8).
IPMI-PET OPTIONS
The following options are specific to ipmi-pet(8). They will be ignored by other tools.- ipmi-pet-username USERNAME
- Specify the default username to use for ipmi-pet(8). If specified, will override the general option username above.
- ipmi-pet-password PASSWORD
- Specify the default password to use for ipmi-pet(8). If specified, will override the general option password above.
- ipmi-pet-k_g str
- Specify the default BMC key (K_g) to use for ipmi-pet(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- ipmi-pet-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for ipmi-pet(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- ipmi-pet-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for ipmi-pet(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- ipmi-pet-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for ipmi-pet(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- ipmi-pet-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for ipmi-pet(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see ipmi-pet(8) manpage for available workarounds.
- ipmi-pet-verbose-count COUNT
- Specify default verbose count to use for ipmi-pet(8).
- ipmi-pet-output-event-severity ENABLE|DISABLE
- Specify if ipmi-pet should output the event severity state by default.
- ipmi-pet-output-event-state ENABLE|DISABLE
- Specify if ipmi-pet should output the event state state by default.
- ipmi-pet-event-state-config-file FILE
- Specify the default event state configuration file.
- ipmi-pet-interpret-oem-data ENABLE|DISABLE
- Specify if ipmi-pet should attempt to interpret OEM data by default or not.
- ipmi-pet-entity-sensor-names ENABLE|DISABLE
- Specify if output of sensor names should include entity ids and instances by default or not.
- ipmi-pet-no-sensor-type-output ENABLE|DISABLE
- Specify if output of the sensor type should be output by default or not.
- ipmi-pet-comma-separated-output ENABLE|DISABLE
- Specify if output should be comma separated by default or not.
- ipmi-pet-no-header-output ENABLE|DISABLE
- Specify if column headers should be output by default or not.
- ipmi-pet-non-abbreviated-units ENABLE|DISABLE
- Specify if output should have units abbreviated by default or not.
IPMI-RAW OPTIONS
The following options are specific to ipmi-raw(8). They will be ignored by other tools.- ipmi-raw-username USERNAME
- Specify the default username to use for ipmi-raw(8). If specified, will override the general option username above.
- ipmi-raw-password PASSWORD
- Specify the default password to use for ipmi-raw(8). If specified, will override the general option password above.
- ipmi-raw-k_g str
- Specify the default BMC key (K_g) to use for ipmi-raw(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- ipmi-raw-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for ipmi-raw(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- ipmi-raw-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for ipmi-raw(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- ipmi-raw-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for ipmi-raw(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- ipmi-raw-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for ipmi-raw(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see ipmi-raw(8) manpage for available workarounds.
IPMI-SEL OPTIONS
The following options are specific to ipmi-sel(8). They will be ignored by other tools.- ipmi-sel-username USERNAME
- Specify the default username to use for ipmi-sel(8). If specified, will override the general option username above.
- ipmi-sel-password PASSWORD
- Specify the default password to use for ipmi-sel(8). If specified, will override the general option password above.
- ipmi-sel-k_g str
- Specify the default BMC key (K_g) to use for ipmi-sel(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- ipmi-sel-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for ipmi-sel(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- ipmi-sel-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for ipmi-sel(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- ipmi-sel-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for ipmi-sel(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- ipmi-sel-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for ipmi-sel(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see ipmi-sel(8) manpage for available workarounds.
- ipmi-sel-verbose-count COUNT
- Specify default verbose count to use for ipmi-sel(8).
- ipmi-sel-types TYPE-LIST
- Specify default types to show SEL events for. Multiple types can be specified separated by whitespace. Users may specify sensor types by string or by number (decimal or hex). Please see ipmi-sel(8) --list-types option to see possible string input types.
- ipmi-sel-exclude-types ENSOR-TYPES-LIST Specify
- default sensor types to not show SEL events for. Multiple sensor types can be specified separated by whitespace. Users may specify sensor types by string or by number. Please see ipmi-sel(8) --list-types option to see possible string input types.
- ipmi-sel-system-event-only ENABLE|DISABLE
- Specify if output should only include system event records.
- ipmi-sel-oem-event-only ENABLE|DISABLE
- Specify if output should only include OEM event records.
- ipmi-sel-output-manufacturer-id ENABLE|DISABLE
- Specify if output of OEM event records should include manufacturer ID by default or not.
- ipmi-sel-output-event-state ENABLE|DISABLE
- Specify if ipmi-sel should output the event state state by default.
- ipmi-sel-event-state-config-file FILE
- Specify the default event state configuration file.
- ipmi-sel-interpret-oem-data ENABLE|DISABLE
- Specify if ipmi-sel should attempt to interpret OEM data by default or not.
- ipmi-sel-output-oem-event-strings ENABLE|DISABLE
- Specify if ipmi-sel should output OEM event strings by default or not.
- ipmi-sel-entity-sensor-names ENABLE|DISABLE
- Specify if output of sensor names should include entity ids and instances by default or not.
- ipmi-sel-no-sensor-type-output ENABLE|DISABLE
- Specify if output of the sensor type should be output by default or not.
- ipmi-sel-comma-separated-output ENABLE|DISABLE
- Specify if output should be comma separated by default or not.
- ipmi-sel-no-header-output ENABLE|DISABLE
- Specify if column headers should be output by default or not.
- ipmi-sel-non-abbreviated-units ENABLE|DISABLE
- Specify if output should have units abbreviated by default or not.
- ipmi-sel-legacy-output ENABLE|DISABLE
- Specify if output should be in legacy format by default or not.
IPMI-SENSORS OPTIONS
The following options are specific to ipmi-sensors(8). They will be ignored by other tools.- ipmi-sensors-username USERNAME
- Specify the default username to use for ipmi-sensors(8). If specified, will override the general option username above.
- ipmi-sensors-password PASSWORD
- Specify the default password to use for ipmi-sensors(8). If specified, will override the general option password above.
- ipmi-sensors-k_g str
- Specify the default BMC key (K_g) to use for ipmi-sensors(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- ipmi-sensors-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for ipmi-sensors(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- ipmi-sensors-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for ipmi-sensors(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- ipmi-sensors-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for ipmi-sensors(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- ipmi-sensors-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for ipmi-sensors(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see ipmi-sensors(8) manpage for available workarounds.
- ipmi-sensors-verbose-count COUNT
- Specify default verbose count to use for ipmi-sensors(8).
- ipmi-sensors-quiet-readings ENABLE|DISABLE
- Specify if sensor reading values and thresholds should not be output by default.
- ipmi-sensors-record-ids ECORD-IDS-LIST
- Specify default record ids to show sensor outputs for. Multiple record ids can be specified separated by whitespace.
- ipmi-sensors-exclude-record-ids ECORD-IDS-LIST
- Specify default record ids to not show sensor outputs for. Multiple record ids can be specified separated by whitespace.
- ipmi-sensors-types TYPE-LIST
- Specify default types to show sensor outputs for. Multiple types can be specified separated by whitespace. Users may specify sensor types by string or by number (decimal or hex). Please see ipmi-sensors(8) --list-types option to see possible string input types.
- ipmi-sensors-exclude-types ENSOR-TYPES-LIST Specify
- default sensor types to not show sensor outputs for. Multiple sensor types can be specified separated by whitespace. Users may specify sensor types by string or by number. Please see ipmi-sensors(8) --list-types option to see possible string input types.
- ipmi-sensors-bridge-sensors ENABLE|DISABLE
- Specify if non-BMC sensors should be bridged by default or not.
- ipmi-sensors-shared-sensors ENABLE|DISABLE
- Specify if shared sensors should be output by default or not.
- ipmi-sensors-interpret-oem-data ENABLE|DISABLE
- Specify if ipmi-sensors should attempt to interpret OEM data by default or not.
- ipmi-sensors-ignore-not-available-sensors ENABLE|DISABLE
- Specify if ipmi-sensors should ignore not-available (i.e. N/A) sensors by default.
- ipmi-sensors-ignore-unrecognized-events ENABLE|DISABLE
- Specify if ipmi-sensors should ignore unrecognized events (i.e. 'Unrecognized Event') in sensors output by default.
- ipmi-sensors-output-event-bitmask ENABLE|DISABLE
- Specify if ipmi-sensors should output event bitmasks instead of string representations by default.
- ipmi-sensors-output-sensor-state ENABLE|DISABLE
- Specify if ipmi-sensors should output the sensor state by default.
- ipmi-sensors-sensor-state-config-file FILE
- Specify the default sensor state configuration file.
- ipmi-sensors-entity-sensor-names ENABLE|DISABLE
- Specify if output of sensor names should include entity ids and instances by default or not.
- ipmi-sensors-output-sensor-thresholds ENABLE|DISABLE
- Specify if ipmi-sensors should output sensor thresholds by default.
- ipmi-sensors-no-sensor-type-output ENABLE|DISABLE
- Specify if output of the sensor type should be output by default or not.
- ipmi-sensors-comma-separated-output ENABLE|DISABLE
- Specify if output should be comma separated by default or not.
- ipmi-sensors-no-header-output ENABLE|DISABLE
- Specify if column headers should be output by default or not.
- ipmi-sensors-non-abbreviated-units ENABLE|DISABLE
- Specify if output should have units abbreviated by default or not.
- ipmi-sensors-legacy-output ENABLE|DISABLE
- Specify if output should be in legacy format by default or not.
- ipmi-sensors-ipmimonitoring-legacy-output ENABLE|DISABLE
- Specify if output should be in ipmimonitoring legacy format by default or not.
IPMI-SENSORS-CONFIG OPTIONS
The following options are specific to ipmi-sensors-config(8). They will be ignored by other tools.- ipmi-sensors-config-username USERNAME
- Specify the default username to use for ipmi-sensors-config(8). If specified, will override the general option username above.
- ipmi-sensors-config-password PASSWORD
- Specify the default password to use for ipmi-sensors-config(8). If specified, will override the general option password above.
- ipmi-sensors-config-k_g str
- Specify the default BMC key (K_g) to use for ipmi-sensors-config(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- ipmi-sensors-config-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for ipmi-sensors-config(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- ipmi-sensors-config-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for ipmi-sensors-config(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- ipmi-sensors-config-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for ipmi-sensors-config(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- ipmi-sensors-config-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for ipmi-sensors-config(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see ipmi-sensors-config(8) manpage for available workarounds.
- ipmi-sensors-config-verbose-count COUNT
- Specify default verbose count to use for ipmi-sensors-config(8).
IPMICONSOLE OPTIONS
The following options are specific to ipmiconsole(8). They will be ignored by other tools.- ipmiconsole-username USERNAME
- Specify the default username to use for ipmiconsole(8). If specified, will override the general option username above.
- ipmiconsole-password PASSWORD
- Specify the default password to use for ipmiconsole(8). If specified, will override the general option password above.
- ipmiconsole-k_g str
- Specify the default BMC key (K_g) to use for ipmiconsole(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- ipmiconsole-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for ipmiconsole(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- ipmiconsole-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for ipmiconsole(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- ipmiconsole-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for ipmiconsole(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- ipmiconsole-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for ipmiconsole(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see ipmiconsole(8) manpage for available workarounds.
- ipmiconsole-escape-char CHAR
- Specify the default escape character.
- ipmiconsole-dont-steal ENABLE|DISABLE
- Specify if in use SOL sessions should not be stolen by default.
- ipmiconsole-serial-keepalive ENABLE|DISABLE
- Specify if serial keepalive should be enabled by default.
- ipmiconsole-serial-keepalive-empty ENABLE|DISABLE
- Specify if serial keepalive empty should be enabled by default.
- ipmiconsole-sol-payload-instance NUM
- Specify the default SOL payload instance.
- ipmiconsole-deactivate-all-instances ENABLE|DISABLE
- Specify if SOL deactivate should deactivate all instances by default.
- ipmiconsole-lock-memory ENABLE|DISABLE
- Specify if memory should be locked by default.
IPMIPOWER OPTIONS
The following options are specific to ipmipower(8). They will be ignored by other tools.- ipmipower-username USERNAME
- Specify the default username to use for ipmipower(8). If specified, will override the general option username above.
- ipmipower-password PASSWORD
- Specify the default password to use for ipmipower(8). If specified, will override the general option password above.
- ipmipower-k_g str
- Specify the default BMC key (K_g) to use for ipmipower(8). If specified, will override the general option k_g above. Prefix with '0x' to enter the key in hex.
- ipmipower-authentication-type AUTHENTICATION-TYPE
- Specify the default authentication type to use for ipmipower(8). If specified, will override the general option authentication-type above. The following authentication types are supported: NONE, STRAIGHT_PASSWORD_KEY, MD2, and MD5.
- ipmipower-cipher-suite-id CIPHER-SUITE-ID
- Specify the default cipher suite id to use for ipmipower(8). If specified, will override the general option cipher-suite-id above. The following cipher suite ids are supported: 0, 1, 2, 3, 6, 7, 8, 11, 12.
- ipmipower-privilege-level PRIVILEGE-LEVEL
- Specify the default privilege type to use for ipmipower(8). If specified, will override the general option privilege-level above. The following privilege levels are supported: USER, OPERATOR, ADMIN.
- ipmipower-workaround-flags WORKAROUNDS
- Specify default workaround flags to use for ipmipower(8). If specified, will override the general options workaround-flags above. Multiple workarounds can be specified separated by whitespace. Please see ipmipower(8) manpage for available workarounds.
- ipmipower-on-if-off ENABLE|DISABLE
- Specify if on-if-off functionality is enabled or disabled by default.
- ipmipower-wait-until-on ENABLE|DISABLE
- Specify if wait-until-on functionality is enabled or disabled by default.
- ipmipower-wait-until-off ENABLE|DISABLE
- Specify if wait-until-off functionality is enabled or disabled by default.
- ipmipower-oem-power-type OEM-POWER-TYPE
- Specify OEM power type to be used.
- ipmipower-retransmission-wait-timeout MILLISECONDS
- Specify the default retransmission wait timeout length to use in milliseconds.
- ipmipower-retransmission-backoff-count COUNT
- Specify the default retransmission backoff count to use for retransmissions.
- ipmipower-ping-interval MILLISECONDS
- Specify the default ping interval length to use in milliseconds.
- ipmipower-ping-timeout MILLISECONDS
- Specify the default ping timeout length to use in milliseconds.
- ipmipower-ping-packet-count COUNT
- Specify the default ping packet count size to use.
- ipmipower-ping-percent PERCENT
- Specify the default ping percent value to use.
- ipmipower-ping-consec-count COUNT
- Specify the default ping consecutive count value to use.
FILES
/etc/freeipmi//freeipmi.confREPORTING BUGS
Report bugs to <freeipmi-users [at] gnu.org> or <freeipmi-devel [at] gnu.org>.COPYRIGHT
Copyright © 2003-2012 FreeIPMI Core Team.FreeIPMI is free software; you can redistribute it and/or modify it under the terms of the GNU General Public License as published by the Free Software Foundation; either version 3 of the License, or (at your option) any later version.
SEE ALSO
freeipmi(7), bmc-config(8), bmc-device(8), bmc-info(8), bmc-watchdog(8), ipmi-chassis(8), ipmi-fru(8), ipmi-oem(8), ipmi-pef-config(8), ipmi-raw(8), ipmi-sel(8), ipmi-sensors(8), ipmi-sensors-config(8), ipmiconsole(8), ipmipower(8)http://www.gnu.org/software/freeipmi/