hpialarms (1) Linux Manual Page
NAME
hpialarms – A openhpi sample application that shows "Alarm Control" management instruments
SYNOPSIS
hpialarms[-D id][-N host[:port]][-C<cfgfile>]
[-a 1 | 0][-b 1 | 0][-c 1 | 0][-m 1 | 0][-n 1 | 0][-p 1 | 0][-i n][-o][-X][-h] hpialarms[--domain = id][--host = host[:port]][--cfgfile = file]
[--diska = 1 | 0][--diskb = 1 | 0][--critical = 1 | 0][--major = 1 | 0]
[--minor = 1 | 0][--power = 1 | 0][--chassisid = n][--all][--debug][--help]
DESCRIPTION
hpialarms walks the RPT (Resource Presence Table) for resources that have “Alarm Control” management instruments (SAHPI_CTRL_LED).
If no domain or host is selected, hpialarms uses the default domain as specified in the openhpiclient.conf file.
OPTIONS
(No Option) Display alarm states
Help Options:
- -h, –help
- Show help options
Application Options:
- -c 1|0, –-critical=1|0
- Set critical alarm on|off
- -m 1|0, –-major=1|0
- Set major alarm on|off
- -n 1|0, –-minor=1|0
- Set minor alarm on|off
- -a 1|0, –-diska=1|0
- Set diska alarm on|off
- -b 1|0, –-diskb=1|0
- Set diskb alarm on|off
- -p 1|0, –-power=1|0
- Set power alarm on|off
- -i n, –-chassisid=n
- Set chassis id on for n seconds
- -o, –-all
- Set all alarms off
- -D nn, –domain=nn
- Select domain id nn
- -X, –debug
- Display debug messages
- -N "host[:port]", –host="host[:port]"
- Open session to the domain served by the daemon at the specified URL (host:port). This option overrides the OPENHPI_DAEMON_HOST and OPENHPI_DAEMON_PORT environment variables. If host contains ‘:’ (for example IPv6 address) then enclose it in square brackets. For example: “[::1]” or “[::1]:4743”.
- -C "file", –cfgfile="file"
- Use passed file as client configuration file. This option overrides the OPENHPICLIENT_CONf environment variable.
SAMPLE OUTPUT
hpialarmpanel ver 0.6 RptInfo : UpdateCount = 5, UpdateTime = 8a2dc6c0 rptentry[0] resourceid = 1 tag : Mullins
RDR[45] : ctltype = 2 : 1 oem = 0 Chassis Identify Control
RDR[48] : ctltype = 0 : 1 oem = 10 Front Panel Power Alarm LED state = off
RDR[51] : ctltype = 0 : 1 oem = 13 Front Panel Minor Alarm LED state = ON
RDR[46] : ctltype = 0 : 0 oem = 0 Cold Reset Control
RDR[49] : ctltype = 0 : 1 oem = 11 Front Panel Critical Alarm LED state = off
RDR[50] : ctltype = 0 : 1 oem = 12 Front Panel Major Alarm LED state = off
SEE ALSO
hpi_shell
hpidomain hpigensimdata hpireset hpitop
hpiel hpiinv hpisensor hpitree
hpievents hpionIBMblade hpisettime hpiwdt
hpifan hpipower hpithres hpixml
ohdomainlist ohhandler ohparam
AUTHORS
Authors of this man page:
Peter D Phan(pdphan[at] users.sourceforge.net)
Ulrich Kleber(ulikleber[at] users.sourceforge.net)
Anton Pak(avpak[at] users.sourceforge.net)